Model 575 - Data Logger System

The Flight Systems Service Advantage provides data-logging and real-time presentation features for the Flight Systems Model 550 Engine Saver® and Model 565 Engine Saver® w/Gauges.

Data Logger Unit shown with Optional LCD Touch-Screen Display

The Service Advantage System Monitors:

  • Engine RPM
  • Engine Run-Time
  • Oil Pressure
  • Crankcase Pressure
  • Coolant Pressure
  • Coolant Temperature
  • Turbo Pressure

Features:

  • Operates Under Extreme Temperatures
  • Set Points for Calibration and Alarms
  • Password Protection
  • Real Time Clock
  • RS232 Serial Port Interface
  • Interconnect and Power Cabling
  • Custom Data Collection Periods

Options:

  • Service Advantage LCD Real-Time Display Screen
  • Service Advantage LCD Touch Screen Display (Shown)
  • Mil Specific Supplies
  • Multi-Drop RS485 Serial Port
  • Wide Variety of NEMA Enclosures
  • Dial-Out Pager Notification

Specifications:

Physical Data:
Card Cage Size: 9.75 x 4.6 x 4.1 (inch)
Card Cage Material: 16 Gauge Epoxy Coated Steel
Power Source: 12 VDC
LCD Monitor Size: 8.6 x 4.8 x .75 (inch)
 
Operating Temperature:
Card Cage: -40 to 85 deg. C
LCD Monitor: -20 to 60 deg. C
 
Power Source: 12 VAC or 15 VDC +/- 15%
 
Loop Supply: Isolated, regulated, fused 24 VDC
 
Surge Suppression: Optically Isolated (meets IEEE)
 
Input/Output Modules:
Analog Inputs: 8 Channels per Module
  12 bit Successive Approximation
  Optically Isolated
  0 to 5 VDC or 0 to 20 mA
  Factory Calibrated
 
Analog Outputs: 4 Channels per Module
  12 bit Successive Approximation
  Optically Isolated
  0 to 5 VDC or 0 to 20 mA
  Factory Calibrated
 
Digital Inputs: 8 Channels Per Module
  Optically Isolated
  120 VAC or 24 VDC
  500 PPS pulse counting
 
Digital Outputs: 8 Channels Per Module
  3 or 10 Amp Relays
  PWM or One Shot w/ 1 ms res.